<< Click to Display Table of Contents >> Operator > Query tool reports > Objects with dissimilar operation state |
The report Objects with abnormal operation state, is a fixed column report, showing all switch devices where the actual state differs from the normal state.
In this report it is possible to use the checkbox Filter out low voltage (u < 1kV) When the checkbox is checked no low voltage switch devices will be displayed in the search result.
As for all reports in dpSpatial it is possible to sort the table on any column combination.
Column |
Description |
---|---|
ID |
The switch device ID. |
N.state |
The normal switch device state (0 = Open, 1 = Closed). |
A.state |
The actual switch device state (0 = Open, 1 = Closed). |
Placed in |
The object in which the switch device is located. |
Outage ID |
The dpSpatial internal outage ID. |
Performed |
The date/time when the last operation on the device was performed. |
Signature |